Full Text CEPIS/OPS/OMS

Pollution limits for discharge of tennery effluents into water bodies and sewer

ARGENTINA
Parameter

Surface

Sewer
pH
Temperature ºC
Suspended solids mg/l
Settleable solids ml/l
BOD5 mg 02/l
COD mg/l
5.5-10.0
45

0.5
50
20

Sulphide mg S2-/l
Chrome (lll) mg/l
Chrome (IV) mg/l
Chrome total mg/l
1
2
0.2
2

2


Chlorides mg/l
Sulphates mg/l
Ammonia mg N/l
TNK mg N/l
Oil/grease mh/l
Phenols mg/l




100
0.05-0.5

Solvents mg/l:
Hydrocarbons mg/l
Nitrogenous mg/l
Chlorimated mg/l



Pollution limits for discharge of tennery effluents into water bodies and sewer

AUSTRALIA
Parameter

Surface

Sewer
pH
Temperature ºC
Suspended solids mg/l
Settleable solids ml/l
BOD5 mg 02/l
COD mg/l
6.0- 9.0
45
60

40

6.0 - 10.0
38
*

*

Sulphide mg S2-/l
Chrome (lll) mg/l
Chrome (IV) mg/l
Chrome total mg/l



0.3
1-5


1-20
Chlorides mg/l
Sulphates mg/l
Ammonia mg N/l
TNK mg N/l
Oil/grease mh/l
Phenols mg/l
*




0.05-0.5
*
1500
50-200

100-1000
10-100
Solvents mg/l:
Hydrocarbons mg/l
Nitrogenous mg/l
Chlorimated mg/l

none
none
none

none
none
none


Pollution limits for discharge of tennery effluents into water bodies and sewer

AUSTRIA
Parameter

Surface

Sewer
pH
Temperature ºC
Suspended solids mg/l
Settleable solids ml/l
BOD5 mg 02/l
COD mg/l
6.5- 8.5
30
30

30
200¤
6.5 - 8.5
30




Sulphide mg S2-/l
Chrome (lll) mg/l
Chrome (IV) mg/l
Chrome total mg/l
0.5
4
0.1
1
2
40
0.1
1
Chlorides mg/l
Sulphates mg/l
Ammonia mg N/l
TNK mg N/l
Oil/grease mh/l
Phenols mg/l


0.5

20
0.5

200
20

100
0.5
Solvents mg/l:
Hydrocarbons mg/l
Nitrogenous mg/l
Chlorimated mg/l
10



20



Index
About CEPIS - Repidisca-Technical Information - Services
Databases Search - Advisory services request

Date upgrated Set/25/97. Coments to Webmaster
HOME