Full Text CEPIS/OPS/OMS

Pollution limits for discharge of tennery effluents into water bodies and sewer

SOUTH AFRICA
Parameter

Surface

Sewer
pH
Temperature ºC
Suspended solids mg/l
Settleable solids ml/l
BOD5 mg 02/l
COD mg/l
5.5-9.5

25

10

5.5-9.0
43
2000-4000


2000-5000
Sulphide mg S2-/l
Chrome (lll) mg/l
Chrome (IV) mg/l
Chrome total mg/l
1

0.05
0.5
5-50



Chlorides mg/l
Sulphates mg/l
Ammonia mg N/l
TNK mg N/l
Oil/grease mh/l
Phenols mg/l


10




500-1000
20-30

50-100

Solvents mg/l:
Hydrocarbons mg/l
Nitrogenous mg/l
Chlorimated mg/l









Pollution limits for discharge of tennery effluents into water bodies and sewer

SPAIN
Parameter

Surface

Sewer
pH
Temperature ºC
Suspended solids mg/l
Settleable solids ml/l
BOD5 mg 02/l
COD mg/l
5.5-9.5
30
80

40
160
5.5-9.5
30
300

300
500
Sulphide mg S2-/l
Chrome (lll) mg/l
Chrome (IV) mg/l
Chrome total mg/l
1

0.2
2
2

0.5
4
Chlorides mg/l
Sulphates mg/l
Ammonia mg N/l
TNK mg N/l
Oil/grease mh/l
Phenols mg/l
2000
2000
15

20
0.5
2000
2000
50

40
1
Solvents mg/l:
Hydrocarbons mg/l
Nitrogenous mg/l
Chlorimated mg/l
2



6




Pollution limits for discharge of tennery effluents into water bodies and sewer

SWITZERLAND
Parameter

Surface

Sewer
pH
Temperature ºC
Suspended solids mg/l
Settleable solids ml/l
BOD5 mg 02/l
COD mg/l
6.5-8.5
30
20

20

6.0-9.5
40




Sulphide mg S2-/l
Chrome (lll) mg/l
Chrome (IV) mg/l
Chrome total mg/l
0.1
2
0.1
2
1
2
0.5
2
Chlorides mg/l
Sulphates mg/l
Ammonia mg N/l
TNK mg N/l
Oil/grease mh/l
Phenols mg/l
200



20
5

300



5
Solvents mg/l:
Hydrocarbons mg/l
Nitrogenous mg/l
Chlorimated mg/l

20

0.1

20

0.1

Index
About CEPIS - Repidisca-Technical Information - Services
Databases Search - Advisory services request

Date upgrated Set/25/97. Coments to Webmaster